{"product_id":"xh-w3005-digital-humidity-controller-220v","title":"XH-W3005 Digital Humidity Controller 220V متحكم رطوبة","description":"\u003cp\u003eXH-W3005 Digital Humidity Controller 220V. Compact humidity control module in a plastic housing (IP22) designed for straightforward two-point On\/Off humidity regulation. The controller continuously displays real-time relative humidity and accepts an SHT20 sensor probe (1 meter). Input power options include 12V DC, 24V DC, or 230V AC; maximum output current is 10A with direct load switching up to 120W.\u003c\/p\u003e\u003cp\u003eKey specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eHousing material: Plastic (IP22)\u003c\/li\u003e\n\u003cli\u003eMeasurement range: 0 to 99% RH\u003c\/li\u003e\n\u003cli\u003eMeasuring accuracy: 0.1% RH\u003c\/li\u003e\n\u003cli\u003eHumidity accuracy: 0.2% RH\u003c\/li\u003e\n\u003cli\u003eInput sensor: SHT20 with 1 m probe\u003c\/li\u003e\n\u003cli\u003eInput power supply: 12V DC \/ 24V DC \/ 230V AC\u003c\/li\u003e\n\u003cli\u003eOutput: Direct 2-point On\/Off\u003c\/li\u003e\n\u003cli\u003eOutput power: 120W\u003c\/li\u003e\n\u003cli\u003eOutput current max: 10A\u003c\/li\u003e\n\u003cli\u003eSize: 60 x 45 x 31 mm\u003c\/li\u003e\n\u003cli\u003eMounting: DIN-rail or wall surface\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eOperation notes and indicators: when connected to power, press UP and DOWN simultaneously for more than 3 seconds to display 888 and restore factory settings. A display reading of \"LLL\" indicates a sensor fault and requires sensor inspection. A reading of \"HHH\" indicates humidity above the measurable range. The display always shows real-time humidity. The controller turns On when Start %RH is less than the termination humidity and turns Off when Start %RH is greater than the termination humidity.\u003c\/p\u003e\u003cp\u003eParameter settings: to set Start humidity, press UP to show the Start value, then long-press for about 3 seconds until it flashes and adjust with UP or DOWN. To set Stop humidity, press DOWN to show the Stop value, then long-press for about 3 seconds until it flashes and adjust with UP or DOWN. Restoring factory settings is performed by pressing UP and DOWN together until 888 appears, after which the unit will automatically detect humidity.\u003c\/p\u003e","brand":"Electronic Service Center","offers":[{"title":"Default Title","offer_id":42953892364471,"sku":null,"price":50.0,"currency_code":"LYD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0639\/4010\/0279\/files\/IMG-2057.png?v=1717701151","url":"https:\/\/esclibya.com\/ar-ly\/products\/xh-w3005-digital-humidity-controller-220v","provider":"Electronic Service Center","version":"1.0","type":"link"}